Hygienic Double Tube Heat Exchangers | HRS Heat Exchangers

Hygienic Double Tube Heat Exchangers – HRS DTA Series

The HRS DTA Series is a complete stainless steel double tube heat exchanger designed for hygienic applications.

The product flows through the inner tubes and the service fluid flows through the surrounding shell. Because of its geometry, the DTA Series is a true counter current heat exchanger.  Using our corrugation technology, both heat transfer and efficiency are increased over standard smooth tube heat exchangers. In addition, potential fouling is minimised.

Bellows are fitted to absorb differential expansion between shell and tube and multiple units can be interconnected for larger applications. Options include frame mounting, insulation and stainless steel cladding.

HRS DTA Series is suitable for viscous products with large particulates in suspension. For high viscosity food products like honey, fruit jams and marmalades, please refer to our Annular Space and Scraped Surface Heat Exchangers product range

TECHNICAL DATA

Standard Materials of Construction:

  • Service side: AISI 304 stainless steel
  • Product side: AISI 316L stainless steel
    Other material options available

Standard Connections:

  • Service side: Flange
  • Product side: Clamp
    All flange & clamp types available

Surface Finish:

  • External: Polished
  • Internal: <0.8μ
    Other surface finishes available

Design code and compliance:

  • PD 5500, PED 2014/68/EU, ASME
  • FDA, 3A, TR CU 032, DOSH Compliant

Brochure